phenix.xtriage will reindex data to a common reference set. scaling.input.xray_data.reference.data.file_name F On Apr 25, 2012, at 9:20 AM, jens j birktoft wrote:
Hi Everybody,
Is there a protocol for re-scaling several sets of diffraction data against a common reference set, either native or based on a Fcalc set computed from a common input model. The are from a number of derivatives, are all isomorphus, and are anomalous data . We want to compare the relative peak heights in Fo-Fc and Anom. difference maps
Cheers
Jens
+++++++++++++++++++++++++++++++++++++++++++++++++++ Jens J. Birktoft e-mail: birktoft @ nyu.edu ; Phone: 212-749-5057 +++++++++++++++++++++++++++++++++++++++++++++++++++ _______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb