I am refining a low resolution structure (2.9A) using
phenix.refine. As I continue the refinement Rwork/Rfree are
dropping but my geometry statistics in general are very bad. My
clashscore is getting worst and the RMS(angle) is really high. I
have tried to play with the "wxc_scale" parameter and also ran
phenix selecting the "Optimize X-ray/ADP weight" option. All
attempts end with a RMS(angle) of ~3.8 and a Clashscore of ~190.
Is there a known procedure to deal with this? I feel that my
geometry weighing term is too loose but I don't know exactly how
to tighten it other than decreasing the wxc_scale parameter. I
have gone and manually corrected bad positions before but given
the low resolution nature of the structure the clashes tend to
be reestablished during refinement.
Thank you in advance for your help,
--
Mario Sanches
Postdoctoral Researcher
Samuel Lunenfeld Research Institute
Mount Sinai Hospital
600 University Ave
Toronto - Ontario
Canada
M5G 1X5