I checked my log file and didn't find "automatic adjustment". My main target is mlhl. However, the target function for rigid body is ls_wunit_k1. I didn't choose that. Is LS the default for rigid body?Jianghai+++++++++++++++++++++++++++++++Jianghai Zhu, Ph.DCBR Institute for Biomedical ResearchDepartment of PathologyHarvard Medical School200 Longwood Ave., Boston, MA 02115Ph: 617-278-3211Fx: 618-278-3232+++++++++++++++++++++++++++++++
On Mar 25, 2007, at 10:00 PM, Ralf W. Grosse-Kunstleve wrote:You are right. Somehow, the default target function inrefinement.bulk_solvent_and_scale is LS, not ML.The default (phenix.refine --show-defaults=all) is actually ml.However, if the main target is set to ls the bulk_solvent_and_scaletarget is automatically reset to ls, too. There should be correspondingmessages in the log file ("automatic adjustment").Ralf_______________________________________________phenixbb mailing list_______________________________________________phenixbb mailing list