Hi Maia, As your datasets are in 2 different space groups, you pretty much have to solve the structure in one space group, then transfer information about the structure (model) to the other space group. So...you want to run an autosol run with the MAD data (or as SAD, sometimes that works better if you have a lot of decay) to solve the structure...then you want to build a model if you can in that space group. Then you have to figure out where that model goes in the high-res crystal...you'll use phenix.automr with your model from the low-res crystal to do that. Then you can do cross-crystal averaging with phenix.multi_crystal average to improve the phases (optional). You can also just rebuild the model in the high-res crystal form and you may be done. Good luck! All the best, -Tom T
Hi everyone,
I have a native set to 2.3A resolution and mercury MAD data in a different space group to 3.3A resolution (anomalous signal to 4.2A).
How I can use autosol with the data I have. There is no such example. (Native +MAD)? What is the best strategy in this case?
Maia
_______________________________________________ phenixbb mailing list [email protected] http://www.phenix-online.org/mailman/listinfo/phenixbb