Hi Yarrow,
Hi,
I recently noticed from reviewing the phenix.refine log file that phenix
is scaling the input intensities using the French-Wilson Method. However,
I have already run Truncate in CCP4 and have structure factors in my MTZ.
So it appears that Phenix.refine ignores structure factors and uses
intensities regardless.
The reason I am concerned is that Nat recently mentioned that the default
for the sigma I cutoff is zero. However, The default in Truncate I thought
was -3. If I understand correctly, the treatment in truncate allows weak
reflections to be scaled and converted to structure factors. It seems that
setting the I sigma cutoff to zero would cause you to loose some useable
data. Currently, the sigma_fobs_rejection_criterion and
sigma_ibos_rejection_criterion = None. This is the default I guess which
would be 0. So my questions are:
1. Will setting:
sigma_iobs_rejection_criterion = -3
result in Phenix using a sigma I cutoff of -3?
2. How do I tell phenix to use the structure factors created by Truncate?
Thanks for your help. I apologize if I have some misconceptions as I am
still relatively new to crystallography.
-Yarrow
--
Yarrow Madrona
Graduate Student
Molecular Biology and Biochemistry Dept.
University of California, Irvine
Natural Sciences I, Rm 2403
Irvine, CA 92697
_______________________________________________
phenixbb mailing list
phenixbb@phenix-online.org
http://phenix-online.org/mailman/listinfo/phenixbb