Hi Reza,
Can anyone suggest a resolution to low pass filter the map to? Or is this value empirically determined by screening through a number of resolutions?
รจ
Yes, this is somehow empirically determined.
I think that my predecessors of cryo_fit used to use 15 A, 10 A, 5 A resolution cryo-EM maps successively to avoid being trapped in local minima when they fit ribosome atomic structure into these.
Relevant references:
cascade mdff in https://elifesciences.org/articles/16105
best,
Doo Nam