On Mon, Aug 15, 2011 at 6:04 AM, Francis E Reyes
Got past that part but now a new error
Traceback (most recent call last): File "/usr/local/phenix-dev-842/phenix/phenix/command_line/refine.py", line 11, in <module> command_line.run(command_name="phenix.refine", args=sys.argv[1:]) File "/usr/local/phenix-dev-842/phenix/phenix/refinement/command_line.py", line 96, in run call_back_handler=call_back_handler) File "/usr/local/phenix-dev-842/phenix/phenix/refinement/driver.py", line 1376, in run ncs_manager = self.ncs_manager) File "/usr/local/phenix-dev-842/phenix/phenix/refinement/strategies.py", line 489, in refinement_machine fmodels.fmodel_xray().update_f_part( AttributeError: 'manager' object has no attribute 'update_f_part'
Immediately after bulk solvent modeling and scaling.
The option "use_statistical_model_for_missing_atoms" is disabled until further notice - unfortunately, the current code does not actually warn you before it crashes. I'll fix that now. -Nat