Dear phenixbb,
I'm trying to copy an R-free set from one point mutant structure to my
new data. This had worked previously using the GUI, inputting the
.sca for the new set and the .mtz from the reference data.
For my newest mutant I'm getting the error message:
The unit cell for the Miller array blah/blah:R-free-flags (53.445,
53.547, 161.082, 90, 90, 90) is significantly different than the
output unit cell (54.033, 53.731, 161.804, 90, 90, 90).
Is this difference actually too big to be using the same R-free set?
If the difference is not too big, how do I get the reflection file
editor past this error?
-bob
On Wed, May 19, 2010 at 2:52 PM, Ralf W. Grosse-Kunstleve
Curious, will either of the utilities (iotbx.reflection_file_editor or iotbx.r_free_flags_completion_simple) follow --use-lattice-symmetry-in- r-free-flag-generation that phenix.reflection_file_converter offers?
Yes.
Ralf _______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb