Hi Nat,
Did you select the correct labels in the configuration interface?On Wed, Oct 31, 2012 at 1:29 PM, Subhani Bandara <ramssb17@gmail.com> wrote:
> I have a structure with heavy metals which I would like to refine anomalous
> scattering factors. I could get the f' and f" values from Autosol, when I
> gave the atom name and wavelength. But when I ran refinement with anomalous
> scattering giving .mtz file and pdb file from pHENIX refinement I got the
> error "Invalid combination-F-obs not anomalous, provide anomalous
> reflections or fix all f" values. Then I used reflection file editor of GUI
> to create a mtz file that has anomalous data using the original reflection
> file and the mtz file of refinement. But still it gives an error. I must be
> doing something wrong, but cannot figure out what that is.
There should be four columns (for instance,
"F(+),SIGF(+),F(-),SIGF(-)". It may not automatically select the
anomalous array, even though it probably should in this case.
-Nat
_______________________________________________
phenixbb mailing list
phenixbb@phenix-online.org
http://phenix-online.org/mailman/listinfo/phenixbb