Dear all,I am making the restraints file (CIF) for a ligand with two chiral carbons, using eLBOW (AM1 QM, output: retain original chirality) from a SMILES description and obtain the following:
Atom input_chirality input_smiles output_vol_sign output_R/S output_chirality_pdbC20 S C@H negative S SC37 R C@@H positive S SAlthough the volume_sign in the output cif file correspond to the input chiralities, the output pdb has the wrong chirality for the carbon C37: S instead of the desired R.
I think the "retain original chirality" option is what I need to keep the input chirality, but apparently it doesn't. How should I proceed to get a pdb with the correct chiralities?Best regards,LionelPS: phenix version 1.9-1692, linux X86_64PS2: in REEL, the action "Find unique code" make phenix (not REEL) crash (all windows close) without error message