I was wondering if there a consensus of when it is mandatory to use ncs
in refinement. Is is dependent on:
1. resolution?
2. data-to-parameter ratio?
3. difference between Rcryst & Rfree?
4. something else...
Or does one just do as Pavel states and try both ways ?
Regards,
Kate
Pavel Afonine wrote:
Hi Francis,
Also if anyone has a paper/protocol for NCS refinement, I'd love to
check it out (to figure out which map to fit to).
Just something to keep in mind... I always prefer to run two refinements
in parallel with and without using NCS. It's resolution (and
data-to-parameters ratio) dependent. I've seen a number of cases where
using the NCS is very beneficial and similar number of cases where it's
better to not use NCS (mostly at resolutions ~2-2.5A).
I would also check manually the NCS groups that are found by
phenix.refine automatically. I have some cases where automatic detection
did not yield a good selection.
Pavel.