Dumb question here: When one runs the various twinning tests (e.g. phenix.xtriage), is one meant to use data processed in the higher symmetry SG, or the lower symmetry SG? A concrete example: I can process a data set in a 622 point group w/ reasonable merging statistics, but an abnormally low solvent content raises my suspicions. So do I process as P6, and submit these data to the twinning test? Or do I submit the data processed as P622? Pat --------------------------------------------------------------------------------------- Patrick J. Loll, Ph. D. Professor of Biochemistry & Molecular Biology Director, Biochemistry Graduate Program Drexel University College of Medicine Room 10-102 New College Building 245 N. 15th St., Mailstop 497 Philadelphia, PA 19102-1192 USA (215) 762-7706 [email protected]