Dear Nat, Does that mean in your selection example that both chain A and chain C will be refined with anisotropic ADP or either one or another? I'm a bit confused with selection operator "or". And I was trying to put "and", which did not work. Best wishes, Alex On 21 Mar 2012, at 18:55, Nathaniel Echols wrote:
On Wed, Mar 21, 2012 at 10:48 AM, Alexander Batyuk
wrote: Thank you, I'm trying to do a refinement in GUI and had to look up something in docs. Actually, I was looking for how to select say, chain A with residues 1-10 and all chain C for anisotropic ADP refinement in GUI? It seems that I can select only one chain with certain residues but not two.. Could you point me to the right direction, please?
Hmm, not sure why this wouldn't work. Are you using the graphical editor or typing in the selection manually? The editor seems to work fine in "select range" mode (see image attached). The selection syntax is pretty simple too:
(chain A and resseq 1:10) or (chain C)
-Nat _______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb
-- Alex Batyuk The Plueckthun Lab www.bioc.uzh.ch/plueckthun