Thanks Pavel
that's great - I appreciate it -
all the best
Martyn
--- On Wed, 8/6/11, Pavel Afonine
From: Pavel Afonine
Subject: Re: [phenixbb] refine To: "PHENIX user mailing list" Cc: "MARTYN SYMMONS" Date: Wednesday, 8 June, 2011, 2:04 Hi Martin, I added a line to PDB file header that reports the number of Bijvoet pairs + singles (each pair {F+,F-} is counted as one reflection), so from now on you will get something like this:
REMARK 3 REMARK 3 DATA USED IN REFINEMENT. REMARK 3 RESOLUTION RANGE HIGH (ANGSTROMS) : 1.500 REMARK 3 RESOLUTION RANGE LOW (ANGSTROMS) : 24.677 REMARK 3 MIN(FOBS/SIGMA_FOBS) : 0.00 REMARK 3 COMPLETENESS FOR RANGE (%) : 98.35 REMARK 3 NUMBER OF REFLECTIONS : 31309 REMARK 3 NUMBER OF REFLECTIONS (NON-ANOMALOUS) : 16857 REMARK 3
Similar change is made to phenix.model_vs_data output.
This will be available in next nightly build (which will be available in a day or two):
http://www.phenix-online.org/download/nightly_builds.cgi
version dev-780 and up.
Pavel.
Dear PHENIX guys as a side note to this:
a continuing problem with anomalous data like this is that the header for deposition at the PDB gives statistics relating to the unmerged data - so that seems to consider the F(+) and F(-) as separate reflections. This is a bit misleading and somewhat at variance with usual crystallographic practice.
It also makes it difficult to see easily what is the actual number of reflections refined against. In the best case it will be about half of the reported but I can't see how you can determine exactly without going to the data to see what
On 6/7/11 1:43 AM, MARTYN SYMMONS wrote: proportion of both anomalous pairs were collected in each resolution range. It also inflates the count of Rfree data by the same factor - which gives a misleading impression.
A workaround would be to redo the
refinement at the end with the anomalous data merged and give the PDB those statistics. Presumably you will have to do this to give an analysis based on merged data for 'Table I' in the paper on the structure.
All the best Martyn
--- On Mon, 6/6/11, Thomas C. Terwilliger
wrote:
From: Thomas C. Terwilliger
Subject: Re: [phenixbb] refine To: "Nora Cronin" Cc: "PHENIX user mailing list" Date: Monday, 6 June, 2011, 21:47 Hi Nora, I'm sorry for the trouble!
Here is the easy way out: extract the appropriate
of data from your HG_28_scala3.mtz and make a new file with
you won't need to specify any data columns and it should run:
phenix.reflection_file_converter HG_28_scala3.mtz \ HG_28_ano_data.mtz --label="I_28(+)" --mtz-root-label="I_28"
I would like to fix the underlying problem however...
I was not able to figure out what combination of data files you have that produced this ending. Normally AutoSol should
columns them. Then print
something like this at the end of this failed run:
----------------------------------------- AutoSol Input failed Sorry...could not figure out which data to use.. For SAD datasets please enter one datafile ...if this is a MAD dataset please specify expt_type='mad'
...to specify a particular set of data you can specify one of the following :
labels='F_28(+) SIGF_28(+) F_28(-) SIGF_28(-)' labels='I_28(+) SIGI_28(+) I_28(-) SIGI_28(-)' -----------------------------------------
In that case, adding one of the lines above should allow it to work.
In your case, autosol got beyond this point and has passed your data file on to phenix.refine, where it has given your error message:
"Multiple equally suitable arrays of observed xray data found."
I couldn't make this happen with some test datasets... so: can you possibly send me (off-list: [email protected])
the files and inputs that led to this problem? Or if you would prefer, the AutoSol_run_1_1.log file?
Thanks!
All the best, Tom T
I'm have a problem with mtz labels
Multiple equally suitable arrays of observed xray data found. Possible choices: HG_28_scala3.mtz:IMEAN_28,SIGIMEAN_28
HG_28_scala3.mtz:I_28(+),SIGI_28(+),I_28(-),SIGI_28(-),merged
Please use
refinement.input.xray_data.labels
to specify an unambiguous substring of the target label. Sorry: Multiple equally suitable arrays of observed xray data found. I've listed all labels
Groups of input data: [1]
NOTE: Deleting group 1 which has no data... closing overall log AutoSol_run_2_/AutoSol_run_2_1.log
List of all anomalous datasets in HG_28_scala3.mtz 'F_28(+) SIGF_28(+) F_28(-) SIGF_28(-)' 'I_28(+) SIGI_28(+) I_28(-) SIGI_28(-)'
List of all datasets in HG_28_scala3.mtz 'F_28 SIGF_28' 'F_28(+) SIGF_28(+) F_28(-) SIGF_28(-)' 'IMEAN_28 SIGIMEAN_28' 'I_28(+) SIGI_28(+) I_28(-) SIGI_28(-)'
List of all individual labels in HG_28_scala3.mtz 'FreeR_flag' 'F_28' 'SIGF_28' 'F_28(+)' 'SIGF_28(+)' 'F_28(-)' 'SIGF_28(-)' 'DANO_28' 'SIGDANO_28' 'IMEAN_28' 'SIGIMEAN_28' 'I_28(+)' 'SIGI_28(+)' 'I_28(-)' 'SIGI_28(-)'
Suggested uses: USE: autosol data file labels='F_28(+) SIGF_28(+) F_28(-) SIGF_28(-)' (program labels: ['I/F', 'sigI/sigF', 'I/F-', 'sigI/sigF-']) (suggested list: ['F_28(+)', 'SIGF_28(+)', 'F_28(-)', 'SIGF_28(-)']) USE: autosol data file labels='I_28(+) SIGI_28(+) I_28(-) SIGI_28(-)' (program labels: ['I/F', 'sigI/sigF', 'I/F-', 'sigI/sigF-']) (suggested list: ['I_28(+)', 'SIGI_28(+)', 'I_28(-)', 'SIGI_28(-)']) USE: autobuild/ligandfit/automr datafile input_labels='F_28 SIGF_28 None None None None None None FreeR_flag' (program labels: ['FP', 'SIGFP', 'PHIB', 'FOM', 'HLA', 'HLB', 'HLC', 'HLD', 'FreeR_flag']) (suggested list: ['F_28', 'SIGF_28', 'None', 'None', 'None', 'None', 'None', 'None', 'FreeR_flag'])
USE: autosol/autobuild refinement file input_refinement_labels='F_28 SIGF_28 FreeR_flag' (program labels: ['FP', 'SIGFP', 'FreeR_flag']) (suggested list: ['F_28', 'SIGF_28', 'FreeR_flag']) USE: autobuild map file input_map_labels='F_28 None None' (program labels: ['FP', 'PHIB', 'FOM']) (suggested list: ['F_28', 'None', 'None'])
USE: automr labels to pass to autobuild input_label_string ='F_28 SIGF_28' (program labels: ['I/F', 'sigI/sigF']) (suggested list: ['F_28', 'SIGF_28'])
USE: automr labels to pass to autobuild input_label_string ='IMEAN_28 SIGIMEAN_28' (program labels: ['I/F', 'sigI/sigF']) (suggested list: ['IMEAN_28', 'SIGIMEAN_28'])
No combination is accepted
Seems obvious but I can't solve it.
Thanks
Nora
Hi Jianghai,
Thanks for the request! All the
reflection_file_reader, so each should be able to read XDS files, including phenix.autosol. If
happy to look into it if you can send me the first few hundred lines of a data file that does not work
On 2 Jun 2011, at 14:32, Thomas C. Terwilliger wrote: phenix tools use the same that does not seem to be the case, I'll be properly.
All the best, Tom T
>> Hi, >> >> In the manual of version
>> read >> XDS_ASCII files with merged data. Do other phenix tools recognized >> XDS_ASCII files? If not, I would
1.7.1, I found out that only phenix.hyss can like to request this feature. For
>> example, let phenix.autosol read XDS_ASCII file with merged or >> unmerged >> data. >> >> Thanks. >> >> -- Jianghai >> >> >> >> >>
>> phenixbb mailing list >> [email protected] >> http://phenix-online.org/mailman/listinfo/phenixbb >>
phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb Dr N B Cronin X-Ray Laboratory Manager Tel. (+44) 020 7153 5445 Section of Structural Biology Fax. (+44) 020 7153 5457 Chester Beatty Laboratories mobile: (+44) 07787554059 The Institute of Cancer Research 237 Fulham Road London SW3 6JB
The Institute of Cancer Research: Royal Cancer Hospital, a charitable Company Limited by Guarantee, Registered in England under Company No. 534147 with its Registered Office at 123 Old Brompton Road, London SW7 3RP.
This e-mail message is confidential and for use by the addressee only. If the message is received by anyone other than the addressee, please return the message to the sender by replying to it and then delete the message from your computer and network.
phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb
_______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb