Hi Dr Echols,
Thank you for the suggestions. I ran the refinement again with default
settings + Rigid body+ Simulated annealing (Cartesian) + Optimize
X-ray/stereochemistry
weight. And the statistics improved! See below:
R-work=0.2348, R-free=0.2855, Bonds=0.003, Angles=0.919.
Ramachandran outliers: 2.5%, Ramachandran favored: 88.1%.
Rotamer outliers: 10%, c-beta outliers: 0
clashscore: 9.06, overall score: 2.84
Now, I am wondering whether there is any suggestion about what to try and
check next to further refine the structure. Thank you so much!
Best,
Wei
On Sun, Jul 28, 2013 at 4:00 PM, Nathaniel Echols
I have a refined structure with phenix. The resolution=3.2 Å. After refinement, the R-work=0.2186, R-free=0.2864, Bonds=0.010, Angles=1.515.
Ramachandran outliers: 4.8%, Ramachandran favored: 80.8%.
Rotamer outliers: 14.5%, c-beta outliers: 2
clashscore: 16.28, overall score: 3.32
To fix the Ramanchandran outliers, in coot, by changing the phi-psi of
On Sun, Jul 28, 2013 at 12:44 PM, Wei Shi
wrote: the outliers, I could manage to move most of them to the allowed positions. But, after another refinement in phenix, those outliers come back.
I am wondering whether any of you have any suggestions for me on how to fix these outliers.
Turn on X-ray/stereochemistry weight optimization (for non-GUI users, optimize_xyz_weight=True). That usually fixes the problem.
-Nat _______________________________________________ phenixbb mailing list [email protected] http://phenix-online.org/mailman/listinfo/phenixbb