Hi Enrico,
this works for me:
phenix.fetch_pdb 2gim
phenix.model_statistics 2gim.cif
mmtbx.reduce2 2gim.cif
Something must be lost in communication. Can you provide complete set of steps that lead to the crash?
Pavel
On 2/13/25 13:55, Enrico Ravera wrote:
Dear Pavel, many thanks. It ran until the reduce2 part, where it gives the following error:File "/home/ravera/miniconda3/envs/cctbx/lib/python3.13/site-packages/mmtbx/monomer_library/pdb_interpretation.py", line 1572, in resolve_unexpected
mod_mod_id = mod_dict["NH1NOTPRO"]the file i am parsing is https://files.rcsb.org/view/2GIM.cif
Any clues?
Cheers,
E.
Il giorno gio 13 feb 2025 alle ore 20:42 Pavel Afonine <pafonine@lbl.gov> ha scritto:
Enrico,
here are the steps (check for typos as I was typing all the below from
memory):
> 1) read in a mmcif file (which I think I can do following the tutorial);
pdb_inp = iotbx.pdb.input(file_name = "4znn.pdb") # can be PDB or mmCIF
model = mmtbx.model.manager(model_input = pdb_inp)
> 2) trim the solvent and hydrogen atoms (probably I can do it following
> the tutorial);
model_no_H = model.remove_hydrogens()
model_no_water = model.remove_solvent()
though better:
selection = model.selection("not (element H or element D or water)")
model_trimmed = model.select(selection)
> 3) run reduce2 to get hydrogens in the nuclear positions (no clue);
Run
mmtbx.reduce OR
mmtbx.reduce2 OR
mmtbx.hydrogenate
to add H. I have no idea about the difference between the three commands
(perhaps just the mess that someone has to finally get brave enough to
clean!), but all three are supposed to add H.
Also, you should be able to access the above calls programmatically, at
Python script level, not running in the CL.
> 4) get the full content of the unit cell (no clue).
Do you mean expand to P1 (if original symmetry is not P1)? If so, then
hierarchy = model.get_hierarchy().expand_to_p1()
Happy to answer questions!
Pavel